Release Notes PN 93000459_H Digi One SP, and Digi One IA EOS 82000774_F2 November 12, 2004 INTRODUCTION This is a production release of firmware for the Digi One SP and Digi One IA. These devices provide high-performance serial port connectivity with added EIA-232/422/485 switch selectable support on the serial port. These devices with RFC-2217 support, TCP Server (Reverse telnet/raw), Autoconnect (TCP Client), UDP Serial Client/Server, ARP-ping, Advanced Device Discovery Protocol, and Digi's patented RealPort protocol for COM port control. SUPPORTED PRODUCTS Digi One SP Digi One IA ENHANCEMENTS ne BUG FIXES - The Digi One SP device will reset the flow control to hardware when power cycled - When configured for "Always connect" it will not connect when placed in 422/485 mode. - Setting the IP address through ADDP and rebooting the device may result in the IP address not being saved to NVRAM - UDP 2773 Debug port open when not in use - Rlogin fails to make a proper auto connection from a serial port - rlogin esc character not working - The 'show versions' command cuts off the last character. - Help for CLI in Digi One SP/IA firmware states incorrect base socket values - Keepalive disconnects a connected session where no traffic has passed KNOWN LIMITATIONS - not applicable ADDITIONAL INFORMATION - not applicable HISTORY 93000459_F1: 2004-09-17 ENHANCEMENTS - Enahced the PMODEM ati3 response to include firmware version BUG FIXES - Resolved an issue where the same IP can be assigned to two different devices via DHCP - Allow host names that start with a number in the Web UI - Resolved an issue where TCP socket 2101 refuses connections 93000459_F: 2003-10-30 - Allow HTTP Web UI port to be changed from the default of 80 93000459_E: 2003-06-06 82000774_E - Production Release of firmware ENHANCEMENTS - Command line interface support - DHCP Keepalive - Web user interface port profiles - by default the profile will be custom. It is recommended that the correct profile for your envrionment be selected. This can be done through the wizard (version 1.2 or higher) on the CD, or through the web interface. The new profiles quicken installation process by only enabling applicable parameters for optimal operation. - Base socket configurable with any integer between 1999 to 50000 93000459_D: 2003-1-23 82000774_D - Production Release of firmware * New web user interface * Send serial buffer after timeout 93000459_C: 2002-12-16 82000774_C - Production Release of firmware. * Digi RealPort Protocol Support * Latency Options and Enhancements * Settable Ethernet Speed and Duplex * TCP Keepalive Options and Enhancements * Ability to Kill Connections (Who) * Copy Configuration (CpConf) 93000459_B1: 2002-09-06 82000774_B1 - Minor, internally-found bug fixes. 93000459_B: 2002-08-07 82000774_B - Support for SP hardware. 93000459_B: 2002-06-01 82000774_A - Initial release of firmware for DigiOne IA. 93000459_01: 2002-06-18 82000774_01 - Beta Release of firmware.