ENERGATE Z100 HOME AUTOMATION DRIVER README =============================================================================== ------------------------------------------------------------------------------- =============================================================================== LICENSE ======= Copyright (c) 2009-2011 Digi International Inc., All Rights Reserved This software contains proprietary and confidential information of Digi International Inc. By accepting transfer of this copy, Recipient agrees to retain this software in confidence, to prevent disclosure to others, and to make no use of this software other than that for which it was delivered. This is an published copyrighted work of Digi International Inc. Except as permitted by federal law, 17 USC 117, copying is strictly prohibited. Restricted Rights Legend Use, duplication, or disclosure by the Government is subject to restrictions set forth in sub-paragraph (c)(1)(ii) of The Rights in Technical Data and Computer Software clause at DFARS 252.227-7031 or subparagraphs (c)(1) and (2) of the Commercial Computer Software - Restricted Rights at 48 CFR 52.227-19, as applicable. Digi International Inc. 11001 Bren Road East, Minnetonka, MN 55343 Contents ======== 1. ABOUT 2. REQUIREMENTS 3. FEATURES 4. INSTALLATION 5. TROUBLESHOOTING 6. REFERENCE DOCUMENTATION CHANGES ======= This version of the Z100HA thermostat driver adds compatability with the SE Framework 1.4.0 +. ABOUT ===== The Z100HA thermostat driver makes Energate Z100 thermostats interoperable with the ZigBee Cluster Library Thermostat and Fan Control clusters when accessed through a Digi gateway. This makes Energate Z100 thermostats compatible with Digi's Energy Daytrader iPhone app. REQUIREMENTS ============ The Z100HA driver has been tested with the following devices: Gateway Requirements .--------------------. 1) SE Framework v1.4.0 2) Gateway radio firmware version 0x3123 3) Gateway firmware version 2.10.0.3 Energate Z100 Requirements .--------------------------. 1) Software version 1.8.6 2) Hardware version 1.3 3) ZigBee Firmware Version 1.3.221 FEATURES ======== The Z100HA thermostat driver adds support for reading, writing and discovering the following attributes: Supported Attributes .--------------------. 1) Thermostat Cluster (0x0201) a. Local temperature (0x0000) b. Heating set point (0x0011) c. Cooling set point (0x0012) d. Control sequence of operation (0x001b) e. System mode (0x001c) 2) Fan Control Cluster (0x0202) a. Fan Mode (0x0000) b. Fan Mode Sequence (0x0001) INSTALLATION ============ NOTE: Driver installation should be performed before adding the thermostat to the gateway's network. Option 1: Python Installation Script (requires python 2.4+)/Windows executable Option 2: Manual Installation Option 3: Advanced Installation Python Installation Script .--------------------------. The Z100HA package provides two installer scripts: install.py and \Windows\install.exe. The install.py script may be run on any system with python 2.4 or greater. The install.exe may only be run on windows machines. Usage: ./install.py .\Windows\install.exe usage: %prog [options] idigi_url idigi_username idigi_password gateway_id idigi_url The iDigi instance associated with the gateway where the Z100HA driver will be installed. idigi_username The username of the iDigi user who owns the gateway where the Z100HA driver will be installed. idigi_password The password for idigi_username. gateway_id The last six digits of the MAC address of the gateway where the driver will be installed. Manual Installation .-------------------. 1) Upload Z100HA.zip to the gateway using iDigi. a. Login to iDigi using your iDigi username and password. b. Open the devices page by clicking the device link on the left-hand menu. c. Double click on the target gateway. A device properties tab will open. d. Under the device properties tab click `Python`. e. Click the upload file icon (file icon with an up arrow). f. Select HAZ100.zip from the installation directory. g. Click OK. 2) Configure the gateway. a. Open the web services console by clicking the `Web Services Console` link on the left-hand menu. b. Next to HTTP Method click the `POST` option. c. Paste the following XML into the text box, replacing {{GATEWAY_ID}} with the last six digits of the gateway's mac address (usually present on the bottom of the gateway). +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ WEB/python/Z100HA.zip energate_virtual_thermostat +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ d. Click the send link at the top of the screen. e. Wait 10 seconds. f. Clear the text box. g. Paste the following XML into the text box, replacing {{GATEWAY ID}} with the last six digits of the gateway's mac address (usually present on the bottom of the gateway). +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ EnergateVirtualHAThermostatEndpoint 0x12 +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ h. Click the send link at the top of the screen. 3) The following request may be required to update the device's information. a. Clear the text box. b. Paste the following XML into the text box, replacing {{GATEWAY ID}} with the last six digits of the gateway's mac address (usually present on the bottom of the gateway). +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ c. Click send. Advanced Installation .---------------------. More advanced installers may create their own scripts for updating a gateway with the Z100 Home Automation driver. The iDigi platform supports web interface calls. All web service calls for installing the Z100 Home Automation driver target the url `http://{{your idigi instance url}}/ws/sci` and use the HTTP POST method. The iDigi web services are authenticated using basic http authentication with the credentials associated with the iDigi account that owns the target gateway. 1) Upload Z100HA.zip to the target gateway using the following sci request where {{GATEWAY ID}} is the last 6 digits of the target gateway's mac address and {{BASE 64 ENCODED DATA}} is the Z100HA.zip file bytes encoded using base 64 encoding. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ %s +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 2) Configure the target gateway. a. Send an sci request with the XML from Manual Install 1e. b. Wait 10 seconds. a. Send an sci request with the XML from Manual Install 1g. TROUBLESHOOTING =============== This section describes what to do once the installation has been complete if the Z100 doesn't function as expected. This could mean: 1) The Z100 does not function properly in the Energy Day Trader mobile app. a. The Z100 does not show up a thermostat device. b. The Day Trader application does not display the current temperature, current setpoints, ... etc. of the Z100. c. The Day Trader application does not allow modification of the current temperature, current setpoints, ... etc. of the Z100. 2) The Thermostat Cluster and/or Fan Control cluster attributes of the Z100 are not present in the iDigi Energy APIs. Resolving issues with the Energy Day Trader Application .-------------------------------------------------------. Problems using the Z100 with the Energy Day Trader Application might be solved using the following suggestions. 1) An issue with the internet connection may be causing the problem. Solution: Make sure the device running the Energy Day Trader Mobile app is connected to the internet. 2) The list of devices in the Energy Day Trader is being cached, so updates to the Z100 aren't being propogated to the device. Solution: Clear the device cache. In the device list portion of the application, push the refresh button at the bottom of screen. 3) The Z100 driver installation did not complete successfully. To verify that this is the issue, click on the Z100 device in the device list on the Energy Day Trader Application. Click the `identify` button in the bottom center of the screen. a. If the light on the top of the Z100 turns on, then the thermostat is connected to the gateway and it is likely that the Z100 driver installation did not complete successfully. Continue to `further troubleshooting`. b. If the light does not turn on, some other problem exists. Contact Digi support. Further troubleshooting .-----------------------. It is possible that these problems are the result of an unsuccessful or incomplete installation of the Z100HA driver. 1) If you followed the manual or advanced installations, make sure that each step was followed closely. 2) Attempt rebooting the gateway by holding down the reset button on the side of the gateway for 3 seconds. Wait 3 minutes. If this does not resolve the issues continue to step 3. 3) In the networks section of iDigi, right click on the gateway the Z100HA driver was installed on. Select `Rediscover (clear cache)` and wait for the discovery process to complete. 4) If none of steps 1-3 solved the problem, contact Digi support. RELATED DOCUMENTATION ===================== Digi Products .-------------. 1) iDigi User's guide 2) iDigi Web services programming guide Xbee Protocol .-------------. 1) ZigBee Protocol Specification 2) ZigBee Cluster Library Specification 3) ZigBee Home Automation Public Application Profile